Explore finder
It looks like you're in the USA
Do you wish to stay on the Finder website Canada or would you like to change country? Surfing the Finder USA website will let you find relevant information, such as country specific and local events and promotions.
Types List
Documentation
Approvals
Video

Type 70.11 - Line monitoring relay

  • Positive safety logic (make output contact opens when the measured value is out of limits)
  • All functions and rating can be easily set using the front face selector and trimmer

Type 70.31 - Line monitoring relay

  • Positive safety logic (make output contact opens when the measured value is out of limits)
  • All functions and rating can be easily set using the front face selector and trimmer

Type 70.41 - Line monitoring relay

  • Detects phase failure even in the presence of regenerated voltages
  • Positive safety logic (make output contact opens when the measured value is out of limits)

Type 70.42 - Three-phase line monitoring relay

  • Detects phase failure error even in the presence of regenerated voltages
  • Positive safety logic (make output contact opens when the measured value is out of limits)

Type 70.51 - Current monitoring relay

  • Current detection up to 16 A
  • 24 to 240 V AC/DC supply

Type 70.61 - Voltage monitoring relay

  • Universal use (systems with UN from 208 V to 480 V, 50/60 Hz)
  • Detects phase failure error even in the presence of regenerated voltages

Type 70.61T - Monitoring relay 6A

  • Compliant with EN 45545-2 + A1: 2016 standards (protection against fire and smoke), EN 61373 (resistance to shock and vibration, category 1, class B), EN 50155 (temperature resistance and humidity, class T1)
  • Universal use (systems with UN from 208 V to 480 V, 50/60 Hz)

Type 70.62 - Voltage monitoring relay

  • Universal use (systems with UN from 208 V to 480 V, 50/60 Hz)
  • Detects phase failure error even in the presence of regenerated voltages

Type 70.62T - Monitoring relay 6 - 8A

  • Compliant with EN 45545-2 + A1: 2016 standards (protection against fire and smoke), EN 61373 (resistance to shock and vibration, category 1, class B), EN 50155 (temperature resistance and humidity, class T1)
  • Universal use (systems with UN from 208 V to 480 V, 50/60 Hz)

Type 70.92 - Thermistor temperature sensing relay

  • Selectable activation time (0.5 or 3 s)
  • 24 V AC/DC or 230 V AC supply

ACCESSORIES

020.01

Adaptor for panel mounting

-Plastic
-17.5 mm wide
-For 70.11 and 70.61

011.01

Adaptor for panel mounting

-Plastic
-35 mm wide
-For 70.31, 70.42 and 70.41

060.48

-For relays types 70.11, 70.31, 70.41, 70.42 and 70.62
-48 tags
-6 x 12 mm

022.09

Separator for rail mounting

– plastic

– 9 mm wide

© Copyright 2020 – FINDER S.p.A. sole proprietorship – All Rights Reserved – VAT number IT05732610018